TECNIS PureSee IOL

TECNIS PureSee™ IOL with TECNIS SIMPLICITY™ Delivery System
A purely refractive presbyopia-correcting IOL with continuous-power technology.1 Designed for uninterrupted, high-quality vision, day and night.1,2
TECNIS PureSee™ IOL with TECNIS SIMPLICITY™ Delivery System
A purely refractive presbyopia-correcting IOL with continuous-power technology.1 Designed for uninterrupted, high-quality vision, day and night.1,2
Redefining Vision Needs

Addressing unmet needs of patients and surgeons

Living longer active lifestyles, patients may have a variety of IOL visual needs.3,4

Low level of visual symptoms5
Continuous crisp and clear vision5
Good day and night vision5
Purely Refractive Design

Dysphotopsia profile comparable to monofocal IOLs6

TECNIS PureSee IOL is based on proprietary refractive technology that enables continuous changes in power with a modified refractive design on the posterior optic.

The anterior aspheric optic is designed to compensate spherical aberrations of the cornea, equivalent to any TECNIS IOL.1

Tecnis Symphony[^TM] IOL

TECNIS SymphonyTM IOL

Tecnis Puresee[^TM] IOL

TECNIS PureSeeTM IOL

Tecnis Monofocal 1-Piece IOL

TECNISTM Monofocal 1-Piece IOL

The presbyopia-correcting IOL provides excellent distance, intermediate and a functional near vision.1

Excellent distance, intermediate and functional near vision7,8

PureSee infographic

TECNIS PureSee IOL provides monofocal-like quality of vision9

Provides similar mesopic contrast level compared to TECNIS Eyhance IOL.9

3 month mesopic no glare

3-Month Mesopic No Glare

3-Month Mesopic With Glare

3-Month Mesopic With Glare

Ease of Use

Monofocal IOL-like dysphotopsia profile even in the presence of defocus2

Document TECNIS PureSee[^TM] IOL

Patient Satisfaction

PureSee Graphic Landingpage

Preloaded in the TECNIS SIMPLICITY Delivery System

Simplify lens delivery with TECNIS SIMPLICITY Delivery System preloaded with TECNIS PureSee IOLs.

TECNIS SIMPLICITY™ Delivery System preloaded with TECNIS PureSee™ IOL showing a three-step hydrate, advance, deliver process.

TECNIS Toric II Platform

Toric platform graphic

Lock-in visual performance with TECNIS PureSee Toric II IOL

 

 

Frosted haptic design increases the amount of friction between the lens haptic surface and the capsular bag to lock in the IOL for rotational stability and visual performance12,13.

Engineered for Rotational Stability

Squared and frosted haptic

Excellent mean rotational stability of 0.94º at 3 months after surgery13 and 100% ≤5º rotation at 3 months.13

References

  1. TECNIS PureSee IOL with TECNIS SIMPLICITY Delivery System, Model DEN00V, DFU INT, Z311782, current revision.
  2. Data on File. DOF2023CT4011. Simulations of visual symptoms under defocus for TECNIS PureSee IOLs. 29 March 2023.
  3. UN – Department of Economic and Social Affairs. Leaving No One Behind In An Ageing World – World Social Report 2023. REF2023CT4338.
  4. Szanton SL, et al. Older adults’ favorite activities are resoundingly active: Findings from the NHATS study. Geriatr Nurs 2015;36(2):131-135. REF2021OTH4024.
  5. Grzybowski A, et al. Methods for evaluating quality of life and vision in patients undergoing lens refractive surgery. Graefes Arch Clin Exp Ophthalmol 2019;257:1091-1099. REF2021CT4246.
  6. Data on File. DOF2023CT4012. Photic phenomena evaluation of the TECNIS PureSee IOL using natural images. 29 March 2023.
  7. Data on File. DOF2023CT4016. Simulated VA of the TECNIS PureSee IOL compared to TECNIS Eyhance and TECNIS 1 Piece IOL. 29 March 2023.
  8. Data on File. DOF2023CT4027. Simulated VA of the TECNIS PureSee IOL compared to TECNIS Symfony IOL. 15 March 2023.
  9. Data on File. DOF2023CT4036. Clinical Investigation of the TECNIS Intraocular Lens, Models CV1000 and CV2000. Contrast Sensitivity Outcomes. 17 July 2023. 
  10. Data on File. DOF2023CT4043. Clinical Investigation of the TECNIS IOL, Models C1V000 and C2V000. Patient Satisfaction Outcomes. 18 July 2023.
  11. Delta IOL Delivery System - Human Factors Validation Report. Dec. 12, 2018. REF2019CT4449.
  12. TECNIS PureSee Toric II IOL with TECNIS SIMPLICITY Delivery System, Model DET (DET100-DET600), DFU INT, Z311783, current revision.
  13. Data on File. DOF2021CT4019. Clinical Investigation of Rotational Stability of the TECNIS Toric II IOL - Steele Study - NXGT-202-QROS. 20 Aug. 2021.
2025PP16999