TECNIS PureSee™ IOL


TECNIS PureSeeTM IOL
– A purely refractive presbyopia-correcting IOL with continuous-power technology1
Designed for uninterrupted, high-quality vision, day and night1,2
TECNIS PureSeeTM IOL
Addressing unmet needs of patients and surgeons
Low level of disturbing visual
Continuous crisp and clear vision
Good vision day and night
Dysphotopsia profile comparable to monofocal IOLs6
TECNIS SymphonyTM IOL
TECNIS PureSeeTM IOL
TECNISTM Monofocal 1-Piece IOL
TECNIS PureseeTM IOL Model DENooV
Excellent distance, intermediate and functional near vision7,8
TECNIS PureSee™ IOL provides monofocal-like quality of vision9
3-Month Mesopic No Glare
3-Month Mesopic With Glare
TECNIS PureSee™ IOL
Provides high tolerance to refractive error and delivers good outcomes event under defocus2,14-15
Patients show high satisfaction and recommend the lens16
Preloaded in the TECNIS SIMPLICITY™ Delivery System
For safe and easy delivery17
TECNIS™ Toric II Platform
Lock-in visual performance with TECNIS PureSee™ Toric II IOL
Frosted haptic design increases the amount of friction between the lens haptic surface and the capsular bag to lock in the IOL for rotational stability and visual performance19,20.
TECNIS PureSee™ IOL
TECNISTM Toric II IOL key study results
Exceptional mean rotational stability of 0.94º at 3 months after surgery20 100% ≤5º rotation at 3 months20
REFERENCES
1. TECNIS PureSee™ OptiBlue™ IOL, Model ZEN00V, DfU INT, Z311973, current revision.
2. DOF2023CT4011 – Simulations of visual symptoms under defocus for TECNIS PureSee™ IOLs. 29 March 2023.
3. UN – Department of Economic and Social Affairs. Leaving No One Behind In An Ageing World – World Social Report 2023. REF2023CT4338.
4. Szanton SL, et al. Older adults’ favorite activities are resoundingly active: Findings from the NHATS study. Geriatr Nurs 2015;36(2):131-135. REF2021OTH4024.
5. Grzybowski A, et al. Methods for evaluating quality of life and vision in patients undergoing lens refractive surgery. Graefes Arch Clin Exp Ophthalmol 2019;257:1091-1099. REF2021CT4246.
6. DOF2023CT4012 Photic phenomena evaluation of the TECNIS PureSee™ ™ IOL using natural images. 29 March 2023.
7. DOF2023CT4016 – Simulated VA of the TECNIS PureSee™IOL compared to TECNIS Eyhance™ and TECNIS™ 1-Piece IOL. 29 March 2023.
8. DOF2023CT4027 Simulated VA of the TECNIS PureSee™ IOL compared toTECNIS Symfony™™ IOL. 15 March 2023.
9. DOF2023CT4036 – Clinical Investigation of the TECNIS™ IOL, Models C1V000 and C2V000. Contrast Sensitivity Outcomes. 17 July 2023.
10. DOF2023CT4017 – MTF of the Bausch & Lomb LuxSmart IOL. 28 March 2023.
11. DOF2023CT4018 – MTF of the SIFI MiniWell IOL. 28 March 2023.
12. DOF2023CT4028 – Simulated VA of the TECNIS PureSee™ IOL compared to Vivity. 24 April 2023.
13. DOF2023CT4025 – MTF of TECNIS PureSee™ IOL and other lens models in low-light conditions. 4 April 2023.
14. Black D, et al. Clinical evaluation of tolerance to residual refractive errors following implantation with a refractive extended-depth-of-focus (EDF) IOL. Abstract ESCRS 2023. REF2023CT4129
15. DOF2023CT4041 - Clinical Investigation of the TECNIS™ IOL, Models C1V000 and C2V000. Tolerance to Refractive Error. 17 July 2023.
16. DOF2023CT4043 – Clinical Investigation of the TECNIS™ IOL, Models C1V000 and C2V000. Patient Satisfaction Outcomes. 18 July 2023..
17. TECNIS PureSee™ IOL with TECNIS SIMPLICITY™ Delivery System, Model DEN00V, DfU INT, Z311782, current revision.
18. Delta IOL Delivery System - Human Factors Validation Report. Dec. 12, 2018. REF2019CT4449.
19. TECNIS PureSee™ Toric II IOL with TECNIS SIMPLICITY™ Delivery System, Model DET (DET100-DET600), DfU INT, Z311783, current revision..
20. DOF2021CT4019 - Clinical Investigation of Rotational Stability of the TECNIS™ Toric II IOL - Steele Study - NXGT-202-QROS. 20 Aug. 2021
For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question.
©Johnson & Johnson and its affiliates 2024