IOL INSERTION
Recommended insertion instruments:
- The UNFOLDER™ Platinum 1 Series Implantation System: Intuitive push-and-twist, screw-style insertion designed to simplify lens implantation.
With its squared and frosted haptic design the TECNIS™ Toric II platform delivers exceptional rotational stability.1
TECNIS™ Toric 1-Piece IOL (non-frosted) and TECNIS™ Toric II 1-Piece IOL (frosted)
• 100% of surgeries had less than 5° rotation at 3-months1
• Mean rotation of TECNIS™ Toric II IOL was 0.94° at 3-months postoperatively1
• As much as 31% improved image contrast over AcrySof® IQ I0Ls2
• Proven low-light performance2
• High-quality distance vision1
Optimize your outcomes with the TECNIS Toric Calculator.
Leverage toric IOLs to reduce residual refractive cylinder and increase spectacle independence for distance.3,4
Unlike another leading IOL, TECNIS™ IOL material is not associated with glistenings,5-9 which can inhibit your patients' vision. Glistenings cause light scatter, which can result in a reduction in image contrast.6-10
97% of patients would elect to have the TECNIS™ Toric IOL again.3
OPTIC CHARACTERISTICS11 | ||
Powers: | +5.0 D to +34.0 D in 0.5 diopter increments. | |
Model Numbers: | ZCU100, ZCU15O, ZCU225, ZCU300, ZCU375, ZCU450, ZCU525, ZCU600, ZCU700, ZCU800 | |
Cylinder Powers - IOL Plane: | 1.00 D, 1.50 D, 2.25 D, 3.00 D, 3.75 D, 4.50 D, 5.25 D, 6.00 D, 7.00 D, 8.00 D | |
Cylinder Powers - Corneal Plane: | 0.69 D, 1.03 D, 1.54 D, 2.06 D, 2.57 D, 3.08 D, 3.60 D, 4.11 D, 4.80 D, 5.48 D | |
Diameter: | 6.0 mm | |
Shape: | Biconvex, anterior toric aspheric surface, square optic edge | |
Material: | UV-absorbing hydrophobic acrylic | |
Refractive Index: | 1.47 at 35° C | |
Edge Design: | ProTEC frosted, continuous 360° posterior square edge | |
BIOMETRY | CONTACT ULTRASOUND§ | OPTICAL*,‡ |
A-Constant: | 118.8 | 119.3 |
Theoretical AC Depth: | 5.4 mm | 5.7 mm |
Surgeon Factor:12 | 1.68 mm | 1.96 mm |
HAPTIC CHARACTERISTICS11 | ||
Overall Length: | 13.0 mm | |
Configuration: | Tri-Fix design, modified C, integral with optic | |
Material: | UV-absorbing hydrophobic acrylic | |
Design: | Haptics offset from optic, haptics have a squared and frosted design | |
Recommended insertion instruments:
* Based on average pseudophakic human eye and ‘Holladay et al. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17-24. REF2014CT0092.
‡ Derived from clinical evaluation results of the TECNIS™ 1-Piece IOL Platform for optical biometry.
§ A-Constant theoretically derived for ultrasound biometry.
REFERENCES
1. DOF2021CT4019 – Clinical Investigation of Rotational Stability of the TECNIS™ Toric II IOL – From Study NXGT-202-QROS. 20 Aug. 2021.
2. DOF2015OTH0006 – TECNIS™ and competitor toric IOL MTF data. 4 May 2015.
3. Black D. Efficacy of hydrophobic acrylic toric IOL to correct astigmatism in cataract patients. Presented at ASCRS 2015. REF2015CT0193.
4. Post-Approval Study of the TECNIS™ Toric IOL Extended Cylinder Range (ECR), Models ZCT450, ZCT525 and ZCT600. 30 August 2017. REF2018CT4111.
5. 150 – Data on File – SENSAR™ not associated with glistening – Literature analysis. May 2013. REF2014OTH0002.
6. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010;36(12):2056-2060. REF2015CT0080.
7. Christiansen G, et al. Glistenings in the AcrySof® intraocular lens: Pilot study. J Cataract Refract Surg. 2001;27(5):728-733. REF2014MLT0005.
8. Colin J, et al. Incidence of glistenings with the latest generation of yellow-tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012;38(7):1140-1146. REF2014MLT0006.
9. Gunenc U, et al. Effects on visual function of glistenings and folding marks in AcrySof® intraocular lenses. J Cataract Refract Surg. 2001;27(10):1611-1614. REF2014MLT0011.
10. Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013;4(8):1294-1304. REF2014OTH0139.
11. TECNIS™ Toric II IOL, Model ZCU100-ZCU800 – DfU OUS – Z311613, current revision.
12. Holladay JT. International Intraocular Lens & Implants registry 2003. J Cataract Refract Surg. 2003;29:176-197. REF2016CT0151.
© Johnson & Johnson and its affiliates 2024
For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question.