TECNIS Multifocal IOL +2.75 D

TECNIS™ Multifocal IOL +2.75 D
No two patients are exactly alike, which is why we offer multifocal lens options optimized for varying visual demands. The TECNIS Multifocal IOL +2.75 D delivers outstanding visual quality.

Also available in Toric II.
TECNIS™ Multifocal IOL +2.75 D
No two patients are exactly alike, which is why we offer multifocal lens options optimized for varying visual demands. The TECNIS Multifocal IOL +2.75 D delivers outstanding visual quality.

Also available in Toric II.

Key Features

Outstanding visual quality

Multifocal lenses capable of providing 20/25 or better.1,2

Enhanced functionality

Give your patients a lens designed for real-world performance.1,2

Long-term sustainability

TECNIS IOL material is not associated with glistenings.6
Mature Asian woman smiling with doctor during a eye health appointment

The TECNIS Multifocal IOL +2.75 D is designed with your patients in mind. Optimized for those favoring activities like grocery shopping, it delivers clarity at a reading distance.

Additional product benefits

  • High quality vision across near, intermediate and distance vision*1,2
  • The TECNIS Multifocal IOL +2.75 D delivers increased spectacle independence in low light performance for outstanding outcomes, even at night.**1,2
  • 97% of patients would elect to have the TECNIS Multifocal IOL +2.75 D again.**1
Chart showing the majority of TECNIS IOL subjects report they never or sometimes wear glasses.

How often do you wear glasses?**1,2

Chart showing that more TECNIS IOL subjects report having no difficulty with night vision.

Degree of difficulty with night vision**1,2
(with glasses if you need them)

Give your patients outstanding low-light performance:
90.8% of patients experienced no difficulty with night vision**†1
69.1% of patients experienced no difficulty with glare**†1
57.0% of patients experienced no difficulty with halos**†1

Specifications

TECNIS Multifocal IOL +2.75 D (ZKB00)

OPTIC CHARACTERISTICS

Powers:

+5.0 D to 34.0 D in 0.5 diopter increments

Diameter:

6.0 mm

Shape:

Biconvex, anterior aspheric surface, posterior diffractive surface

Add Power (IOL Plane):

+2.75 D

Add Power (Spec Plane):

+2.01 D

Material:

UV-blocking hydrophobic acrylic

Refractive Index:

1.47 at 35° C

Chromatic Aberration (Abbe Number):

55

Edge Design:

ProTEC frosted, continuous 360° posterior square edge

BIOMETRYCONTACT ULTRASOUNDOPTICAL

A-Constant:

118.8

119.3§

Theoretical AC Depth:

5.40 mm

5.72 mm

Surgeon Factor:8

1.68 mm

1.96 mm

HAPTIC CHARACTERISTICS

Overall Length:

13.0 mm

Style:

C

Material:

UV-blocking hydrophobic acrylic

Design:

Haptics offset from optic

IOL INSERTION
Recommended insertion instruments:

UNFOLDER Platinum 1 Series Delivery System: Intuitive push-and-twist, screw-style insertion designed to simplify lens implantation.

Learn More

Get the latest news and product info from Johnson & Johnson Vision.
Required fields are marked with an asterisk
*
*
*
*
Your Role
*
*
Area of Interest
*
Cataract Surgery
OS Disease
LASIK Surgery
Send me updates and helpful resources via email
*

With your consent, we will use your information to send you information about our products and services tailored to your interests through email. You may withdraw your consent at any time.

Please read our Privacy Policy.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

FOOTNOTES
*TECNIS Multifocal IOLs provide distance and near vision (ZLB00 and ZMB00) or distance and intermediate vision (ZKB00). In combination, the lenses can

provide a full range of vision.

**The questionnaire was not determined to be a psychometrically valid assessment of the concept of spectacle independence.

†On a scale of 1-7, with glasses as needed

‡Value theoretically derived for a typical 20.00 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their

surgical techniques and equipment, experience with the lens model and postoperative results.

§Derived from clinical evaluation results of the TECNIS 1-Piece Platform.

REFERENCES

1. TECNIS Multifocal 1- Piece IOL DFU, Models ZKB00 and ZLB00. Irvine, Calif. Johnson & Johnson Surgical Vision, Inc.
2. TECNIS Multifocal 1- Piece IOL DFU, Model ZMB00. Irvine, Calif. Johnson & Johnson Surgical Vision, Inc.
3. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010;36(12):2056-2060.
4. Christiansen G, et al. Glistenings in the AcrySof® intraocular lens: Pilot study. J Cataract Refract Surg. 2001;27(5):728-733.
5. Colin J, et al. Incidence of glistenings with the latest generation of yellow- tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012;38(7):1140-1146.
6. Gunenc U, et al. Eff ects on visual function of glistenings and folding marks in AcrySof® intraocular lenses. J Cataract Refract Surg. 2001;27(10):1611-1614.
7. Van der Mooren M, Franssen L, Piers P. Eff ects of glistenings in intraocular lenses. Biomed Opt Express. 2013;4(8):1294-1304.
8. Calculated based on Holladay I formula: Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruis RS. A three- part system for refi ning intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1)17-24

INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR THE TECNIS MULTIFOCAL 1-PIECE IOLS, MODELS
ZKB00 AND ZLB00
Rx Only

INDICATIONS
The TECNIS Multifocal 1-Piece Intraocular lenses, Models ZKB00 (+2.75 D) and ZLB00 (+3.25 D), are indicated for primary implantation for the visual correction of aphakia in adult patients with and without presbyopia in whom a cataractous lens has been removed by phacoemulsifi cation and who desire near, intermediate, and distance vision with increased spectacle independence. The intraocular lenses are intended to be placed in the capsular bag.

WARNINGS
Physicians considering lens implantation should weight the potential risk/benefi t ratio for any conditions described in the Directions for Use that could increase complications or impact patient outcomes. Multifocal IOL implants may be inadvisable in patients where central visual fi eld reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. The lens should not be placed in the ciliary sulcus. Inform patients about the possibility that a decrease in contrast sensitivity and an increase in visual disturbances may aff ect their ability to drive a car under certain environmental conditions, such as driving at night or in poor visibility conditions.

PRECAUTIONS
Prior to surgery, inform prospective patients of the possible risks and benefi ts associated with the use of this device and provide a copy of the patient information brochure to patient. The long term eff ects of intraocular lens implantation have not been determined. Secondary glaucoma has been reported occasionally in patients with controlled glaucoma who received lens implants. Do not reuse, resterilize or autoclave.

ADVERSE EVENTS
Only the rate (3.3%) of surgical re- interventions, most of which were non- lens- related, in the ZLB00 (+3.25 D) lens group, was statistically higher than the FDA grid rate (for both first and second eyes).

ATTENTION
Reference the Directions for Use for a complete listing of Indications and Important Safety Information.

INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR TECNIS MONOFOCAL 1-PIECE IOL
INDICATIONS
The TECNIS 1-Piece lens is indicated for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction. These devices are intended to be placed in the capsular bag.

WARNINGS
Physicians considering lens implantation should weigh the potential risk/benefi t ratio for any conditions described in the TECNIS 1-Piece IOL Directions for Use that could increase complications or impact patient outcomes. The TECNIS 1-Piece IOL should not be placed in the ciliary sulcus.

PRECAUTIONS
Do not reuse, resterilize, or autoclave.

ADVERSE EVENTS
In 3.3% of patients, reported adverse events of cataract surgery with the TECNIS 1- Piece IOL included macular edema.

ATTENTION
Reference the Directions for Use for a complete listing of indications and important safety information.

INDICATIONS AND IMPORTANT SAFETY INFORMATION FOR THE UNFOLDER PLATINUM 1 SERIES IMPLANTATION SYSTEM
INDICATIONS
The Model DK7796 Handpiece is used in combination with the Model 1MTEC30 Cartridge to fold and assist in inserting Johnson & Johnson Surgical Vision Acrylic 1- Piece Intraocular Lenses, ONLY into the capsular bag.

CONTRAINDICATIONS
Do not use the handpiece if the rod tip appears nicked or damaged in any way.

WARNINGS
The UNFOLDER Platinum 1 Series Implantation System should be used ONLY with JJSV Acrylic 1- Piece IOLs. Do not use if the cartridge tip is cracked or split prior to implantation. Never release the plunger until the optic body has been completely released from the cartridge tube.

See Full Indications and Important Safety Information.

ATTENTION
Reference the Directions for Use for a complete listing of Indications and Important Safety Information.

PP2023CT5065

Johnson & Johnson MedTech
We support the AdvaMed Code of Ethics on interacting with Healthcare Professionals.
Advamed Logo
© Johnson & Johnson and its affiliates 2024. All rights reserved. This site is published by Johnson & Johnson Vision Care, Inc. and Johnson & Johnson Surgical Vision, Inc., which are solely responsible for its content.

Third party trademarks used herein are trademarks of their respective owners.

Vision Made Possible